{"product_id":"ge-fanuc-ic697cmm711-series-90-70-communication-coprocessor-module","title":"Módulo Coprocessador de Comunicação GE Fanuc IC697CMM711 Série 90-70","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC697CMM711\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunciona como um\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecoprocessador de comunicação de alto desempenho\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esistema PLC GE Fanuc Série 90-70\u003c\/strong\u003e. Equipado com um\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emicroprocessador 80C186 dedicado de 12 MHz\u003c\/strong\u003e, este módulo descarrega as tarefas de comunicação da CPU principal, garantindo\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etempos de varredura consistentes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etroca rápida de dados\u003c\/strong\u003e. Oferece\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eduas portas seriais independentes com conector D-shell de 25 pinos\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eque suportam diversos protocolos industriais, incluindo\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSNP\/SNP-X\u003c\/strong\u003e e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCM\u003c\/strong\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% novo\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee embalado em condição original de fábrica.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetalhes\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMicroprocessador\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 MHz\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80C186\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocolos Suportados\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSNP\/SNP-X\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Mestre\/Escravo),\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Mestre\/Escravo\/Par),\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Escravo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePortas de Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDuas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econexões D-shell de 25 pinos\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTaxas de Baud\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e300 a 19.200 bps\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumo de Corrente no Backplane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e700 mA @ 5 VDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicadores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMódulo OK\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStatus da Porta 1\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStatus da Porta 2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecursos de Controle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBotão de reinicialização no painel frontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0,51 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eVantagens de Engenharia\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDesempenho Otimizado da CPU\u003c\/strong\u003e: O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocessador 80C186 dedicado\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edescarrega a sobrecarga dos protocolos seriais, permitindo que a CPU principal do PLC se concentre totalmente na execução da lógica. Isso garante\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etempos de resposta mais rápidos\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esem atrasos na comunicação.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCombinações Versáteis de Protocolos\u003c\/strong\u003e: As\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eduas portas independentes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epodem ser configuradas para diferentes protocolos. Por exemplo, você pode executar\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSNP na Porta 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara um IHM e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU na Porta 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara coleta de dados, oferecendo uma gateway flexível entre múltiplas redes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguração Definida por Software\u003c\/strong\u003e: Não há\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ejumpers físicos ou chaves DIP\u003c\/strong\u003e. Todos os parâmetros de taxa de baud e protocolo são gerenciados via software (Proficy Machine Edition ou Logicmaster 90-70), simplificando a configuração e a solução de problemas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnóstico Avançado do Sistema\u003c\/strong\u003e: O módulo inclui\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etrês indicadores LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara feedback imediato sobre a saúde do módulo e o tráfego ativo das portas. Se surgirem problemas, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebotão integrado\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epermite a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ere-inicialização rápida do módulo\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esem desligar todo o PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003ePerguntas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Este módulo requer bateria para armazenamento do programa?\u003c\/strong\u003e\u003cbr\u003eNão, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC697CMM711\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enão precisa de bateria. A configuração é recebida diretamente do módulo CPU durante a energização.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Este módulo pode atuar como Mestre Modbus?\u003c\/strong\u003e\u003cbr\u003eNão, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC697CMM711\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuporta\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU apenas no modo Escravo\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Para funcionalidade Mestre Modbus, será necessário um módulo diferente ou um módulo\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprogramável em C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Qual cabo é necessário para as portas de 25 pinos?\u003c\/strong\u003e\u003cbr\u003eO módulo utiliza camadas físicas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-232\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-422\u003c\/strong\u003e ou\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, dependendo da sua configuração. Use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecabos blindados\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econectores D-shell de 25 pinos\u003c\/strong\u003e, cabeados conforme o protocolo e tipo de interface escolhidos.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. É seguro instalar este módulo com o PLC energizado?\u003c\/strong\u003e\u003cbr\u003eNão,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ea energia deve ser desligada\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eda base antes de instalar ou remover o módulo. Inserir o módulo em um backplane energizado pode causar\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003earco elétrico\u003c\/strong\u003e, danificando o coprocessador e módulos adjacentes.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52137091957048,"sku":"IC697CMM711","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC697CMM7112.jpg?v=1775699696","url":"https:\/\/www.automodulexpert.com\/pt\/products\/ge-fanuc-ic697cmm711-series-90-70-communication-coprocessor-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}