{"product_id":"ge-fanuc-digital-mixed-i-o-module-ic694mdl916-ba","title":"GE Fanuc Digital Mixed I\/O Module IC694MDL916-BA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694MDL916-BA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emixed I\/O module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform, combining both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 digital inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 digital outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein a single-slot configuration. Rated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e, this module is ideal for high-current applications, offering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2.0 Amperes per output channel\u003c\/strong\u003e. It can directly drive solenoids, contactors, and high-wattage indicators, eliminating the need for interposing relays. Supplied in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, this module maximizes space in systems with limited backplane slots.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Digital Inputs (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Digital Outputs (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\/Output Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC (24 VDC Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 Amperes per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 VAC (Channel-to-backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 mA from 5V bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 mm x 35 mm x 133 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Slot Utilization\u003c\/strong\u003e: Combines 8 inputs and 8 outputs into a single slot, reducing the need for additional modules and saving backplane space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Drive Capability\u003c\/strong\u003e: Each output can drive up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2A\u003c\/strong\u003e, allowing direct control of solenoids, contactors, and other inductive loads, minimizing hardware complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Spares Management\u003c\/strong\u003e: The mixed I\/O design reduces the number of spare parts required for systems with a small number of I\/O points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Isolation\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e250 VAC isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween field channels and backplane ensures protection from electrical surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect 24V Interface\u003c\/strong\u003e: Interfaces directly with standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24V industrial sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand actuators, offering a wide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e18-30 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of terminal block does this module use?\u003c\/strong\u003e\u003cbr\u003eThe IC694MDL916-BA typically uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20-terminal front-mounted block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g.,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694TBB032\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694TBS032\u003c\/strong\u003e). Verify the wiring diagram to ensure correct terminal assignments for input and output commons.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different voltages for the inputs and outputs?\u003c\/strong\u003e\u003cbr\u003eNo. The module requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24V DC nominal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply for both inputs and outputs. It does not support AC voltages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"-BA\" suffix signify?\u003c\/strong\u003e\u003cbr\u003eThe \"-BA\" suffix indicates an updated hardware revision with optimized circuitry and manufacturing standards, while ensuring full compatibility with earlier IC694MDL916 versions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003cbr\u003eWhile the RX3i platform supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHot Insertion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor I\/O modules, always follow proper safety procedures to prevent unintended machine movement when replacing a live module.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52186647462200,"sku":"IC694MDL916-BA","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC694MDL916-BA1_b02caa00-7bed-42b7-9759-54b148b7ddec.jpg?v=1776130633","url":"https:\/\/www.automodulexpert.com\/ru\/products\/ge-fanuc-digital-mixed-i-o-module-ic694mdl916-ba","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}