{"product_id":"mc-tamt03-51309223-175-honeywell-low-level-input-multiplexer-module","title":"MC-TAMT03 51309223-175 Honeywell Low Level Input Multiplexer Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell MC-TAMT03 Low-Level Input Multiplexer Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to handle sensitive analog signals, particularly from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouples\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand other low-voltage sensors. It supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 input channels\u003c\/strong\u003e, enabling high-density signal acquisition for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed control systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as Honeywell’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTDC3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMoreover, the module features onboard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCold Junction Compensation (CJC)\u003c\/strong\u003e, which enhances measurement accuracy by correcting for ambient temperature variations. In addition, its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erugged design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCE, TUV, UL508\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSA certifications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensure reliable operation in harsh industrial conditions.\u003c\/p\u003e\n\u003cp\u003eThis module is widely used in industries such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical processing\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil refining\u003c\/strong\u003e, where precise temperature control is critical. Therefore, it is a trusted component in high-integrity automation architectures.\u003c\/p\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51309223-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC-TAMT03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-Level Analog Input Multiplexer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.8 cm × 12.1 cm × 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermocouple Signal Acquisition\u003c\/strong\u003e: Captures low-level analog signals from temperature sensors with high precision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed Control Systems (DCS)\u003c\/strong\u003e: Integrates seamlessly into Honeywell’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUCN-based platforms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor centralized monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Automation\u003c\/strong\u003e: Used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical plants\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erefineries\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower stations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor temperature control and diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Input Configurations\u003c\/strong\u003e: Supports up to 16 channels, reducing hardware footprint in control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e: Ensures accurate readings by correcting for ambient temperature effects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor instance, in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbine control system\u003c\/strong\u003e, this module collects temperature data from multiple thermocouples to monitor bearing and casing temperatures. In addition, its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompact design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows easy installation in space-constrained environments.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eQ: What types of sensors are compatible with this module?\u003c\/h3\u003e\n\u003cp\u003eA: It is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouples\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand other\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow-voltage analog sensors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eQ: Does it support Cold Junction Compensation?\u003c\/h3\u003e\n\u003cp\u003eA: Yes, it includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eonboard CJC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor improved measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eQ: Can it be used with Experion PKS systems?\u003c\/h3\u003e\n\u003cp\u003eA: Yes, it is compatible with both legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTDC3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand modern\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms.\u003c\/p\u003e\n\u003ch3\u003eQ: Is the module hot-swappable?\u003c\/h3\u003e\n\u003cp\u003eA: No, the system must be powered down before installation or replacement.\u003c\/p\u003e\n\u003ch3\u003eQ: What is the maximum number of input channels?\u003c\/h3\u003e\n\u003cp\u003eA: The module supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 low-level analog input channels\u003c\/strong\u003e.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":51319664345400,"sku":"MC-TAMT03 51309223-175","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/MC-TAMT03_51309223-175.jpg?v=1762479585","url":"https:\/\/www.automodulexpert.com\/sl\/products\/mc-tamt03-51309223-175-honeywell-low-level-input-multiplexer-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}