{"product_id":"ge-ic200alg630-versamax-thermocouple-mv-input-module","title":"GE IC200ALG630 VersaMax Thermocouple \/ mV Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 100% Brand New GE IC200ALG630 acquires temperature and low-level voltage data for the VersaMax I\/O system. It interfaces with up to seven thermocouple sensors (Types J, K, T, S, R) or measures direct millivolt signals (+\/-19.5mV to +\/-625mV). The module provides 15-bit plus sign resolution and handles cold junction compensation (CJC) via software configuration.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 (Differential)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Types:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThermocouple (J, K, T, S, R), Millivolt (+\/- 19.5, 39, 78.125, 156.25, 312.5, 625 mV)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15 Bits + Sign (16 Bit A\/D)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.15% (Temp), ±0.2% (mV) at 25°C\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e60 ms\/ch @ 60Hz, 70 ms\/ch @ 50Hz\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Comp:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNone, Local (Thermistor), Remote, Fixed\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 VDC @ 125 mA, 3.3 VDC @ 125 mA\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250 VAC Continuous (Field to Logic\/Frame)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConformity Error:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.3°C (±0.5°F)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOK (Green\/AMBER)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Sensor Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module accepts both thermocouples and raw millivolt signals. Engineers configure each channel independently via software, allowing a mix of temperature probes and custom mV transducers (e.g., load cells or pressure transducers with mV output) on one module.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Cold Junction Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports four CJC modes. For highest accuracy, technicians use \"Local\" mode with a thermistor (IC690ACC905) mounted on the terminal carrier or an Interposing Thermocouple Carrier (IC200CHS014) to compensate for terminal block temperature, isolating sensors from module heat.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features 60dB normal mode rejection at 50\/60Hz and 120dB common mode rejection. This ensures stable readings in electrically noisy environments near VFDs or heavy machinery.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOpen Sensor Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module detects open thermocouple wires or broken leads immediately. It reports the fault to the CPU, preventing control action based on invalid temperature data (e.g., full scale reading).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external 24VDC power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200ALG630 draws power from the 5V and 3.3V backplane. It does not require external power for the inputs, though a thermistor power source may be needed for specific Local CJC setups depending on the carrier.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix Thermocouple and mV inputs on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You configure each of the 7 channels independently in the software (Proficy Machine Edition). Set the type to J, K, T, S, R for TC, or \"None\" for mV input, and select the specific mV range for that channel.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat carrier should I use for Thermocouple wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor best results with Local CJC, use the Interposing Thermocouple I\/O Terminal (IC200CHS014) connected via cable to a Connector-Style Carrier (IC200CHS003). You can also use standard terminal carriers (IC200TBMxxx) but you must install the thermistor kit (IC690ACC905) on terminals A9\/A10.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When the system hardware configuration enables RIUP (Removal and Insertion Under Power), the IC200ALG630 supports live replacement without powering down the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52373378466104,"sku":"IC200ALG630","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG6301.jpg?v=1778812152","url":"https:\/\/www.automodulexpert.com\/sr\/products\/ge-ic200alg630-versamax-thermocouple-mv-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}