{"product_id":"ic200alg262e-ge-fanuc-analog-input-module-new-original-stock","title":"IC200ALG262E GE Fanuc Analog Input Module New \u0026 Original Stock","description":"\u003cp\u003eConfigured for analog signal acquisition in Field Control I\/O platforms, the \u003cstrong\u003eGE IC200ALG262E\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG262E\u003c\/strong\u003e Input Module) provides direct physical electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG262E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandardized Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e8 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Deterministic Network Communication and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG262E interfaces with the Field Control backplane bus to facilitate real-time monitoring of current-loop instrumentation. The module is optimized for deterministic network performance, ensuring that analog data packets are refreshed according to the host controller's scan cycle. In multi-module configurations, users must manage I\/O density scaling to ensure the backplane communication velocity remains consistent. Firmware flash compatibility is essential to ensure that the analog-to-digital conversion parameters align with the requirements of the global automation platform, preventing signal drift or latency issues within the control loop.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module require external loop power for the analog inputs?\u003c\/p\u003e\n\u003cp\u003eA: Operation depends on the specific instrumentation connected; however, the module must be wired to ensure the current loop path is completed, whether power is derived from the module or an external isolated source.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module compatible with HART communication?\u003c\/p\u003e\n\u003cp\u003eA: The IC200ALG262E is designed for standard 4-20 mA current input sensing and does not support HART protocol signal pass-through.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize shielded twisted-pair cabling for all current input loops. Terminate shields at a single, verified instrument ground point to prevent the formation of ground loops that could introduce measurement noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegregation:\u003c\/strong\u003e Maintain physical separation between analog input signal wiring and high-current power or AC lines. A minimum distance of 15 cm is recommended to mitigate the risk of electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is properly seated onto the Field Control carrier. Verify that the backplane connector is fully engaged to establish a low-resistance path for data and power transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Verify that the wiring matches the documented terminal assignments for the 8 input points. Ensure that all field connections are torqued to specifications to avoid intermittent resistance in the current loop.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52429906903352,"sku":"IC200ALG262E","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG262E.jpg?v=1779867875","url":"https:\/\/www.automodulexpert.com\/sr\/products\/ic200alg262e-ge-fanuc-analog-input-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}