{"product_id":"is200edisg1a-general-electric-exciter-power-distribution-board-new-original-stock","title":"IS200EDISG1A General Electric Exciter Power Distribution Board | New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200EDISG1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200EDISG1\u003c\/strong\u003e Exciter Power Distribution Board, operates as a dedicated hardware component for power regulation and distribution within EX2100e excitation control systems. This board serves as the critical junction for distributing controlled DC power to the excitation bridge and associated control circuitry.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EDISG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e33 x 10 x 8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eEX2100e Exciter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IS200EDISG1A facilitates system-wide power management through a complex array of distribution traces and protective monitoring circuits. It interfaces with the excitation backplane bus communication velocity to ensure that power-on status and fault conditions are accurately reported to the system controller. Firmware flash compatibility is intrinsically linked to the revision of the excitation control power supply and monitoring logic; improper firmware alignment can cause erroneous voltage regulation feedback, leading the controller to inhibit field excitation for protective purposes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200EDISG1A require manual adjustment for voltage distribution?\u003c\/p\u003e\n\u003cp\u003eA: No, the board is designed with fixed distribution logic. Voltage thresholds and monitoring parameters are handled by the associated EX2100e controller software. Manual adjustments to the physical board are restricted to cable seating and diagnostic test point monitoring.\u003c\/p\u003e\n\u003cp\u003eQ: Can this board be replaced during excitation operation?\u003c\/p\u003e\n\u003cp\u003eA: Replacement of the IS200EDISG1A requires the excitation system to be in a total \"Off\" or \"Maintenance\" state. Because this board manages high-energy field power distribution, attempting replacement while the exciter is online will cause an immediate loss of field voltage and a potential turbine trip.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Stability:\u003c\/strong\u003e Secure the board using all available mounting points on the Exciter Power Distribution rack. Ensure that the backplane connectors are perfectly aligned before pressing the board into place to prevent pin bending.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Verify that all high-current lug connections are tightened to the specified torque requirements to prevent localized overheating due to contact resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the board chassis ground connection is securely bonded to the main cabinet ground bus. This is essential for maintaining a stable potential reference for the board's onboard voltage sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Keep low-voltage control signals physically isolated from the high-power DC distribution lines to prevent capacitive coupling and induced signal noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52493458899256,"sku":"IS200EDISG1A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200EDISG1A1.jpg?v=1781165688","url":"https:\/\/www.automodulexpert.com\/sr\/products\/is200edisg1a-general-electric-exciter-power-distribution-board-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}