The 469 Motor Management Relay is a microprocessor-based device designed to protect and manage medium to large horsepower motors and their associated equipment. This relay features six output relays, which are used for tripping, alarms, and start blocking. It combines motor protection, fault diagnostics, power metering, and RTU (Remote Terminal Unit) functions into a single, cost-effective, drawout package. The following single-line diagram demonstrates the 469's functionality, using ANSI (American National Standards Institute) device numbers for reference.
Specifications
ANALOG CURRENT INPUTS
- Inputs: 0 to 1 mA, 0 to 20 mA, or 4 to 20 mA (settings)
- Input impedance: 226 Ω ±10%
- Conversion range: 0 to 21 mA
- Accuracy: ±1% of full scale
- Type: Passive
- Analog in supply: +24 V DC at 100 mA max.
- Response time: ≤100 ms
DIFFERENTIAL CURRENT INPUTS
- CT primary: 1 to 5000 A
- CT secondary: 1 A or 5 A (settings)
- Burden: <0.2 VA at rated load
- Conversion range: 0.02 to 1 × CT primary
- Nominal frequency: 20 to 70 Hz
- Frequency range: 20 to 120 Hz
- Accuracy: ±0.5% of 1 × CT for 5 A; ±0.5% of 5 × CT for 1 A
-
CT withstand:
- 1 second at 80 × rated current
- 2 seconds at 40 × rated current
- Continuous at 3 × rated current
DIGITAL INPUTS
- Inputs: 9 opto-isolated inputs
- External switch: Dry contact < 400 Ω, or open collector NPN transistor from sensor; 6 mA sinking from internal 4 KΩ pull-up at 24 V DC with Vce < 4 V DC
GROUND CURRENT INPUTS
- CT primary: 1 to 5000 A
- CT secondary: 1 A or 5 A (settings)
- Burden: <0.2 VA at rated load for 1 A or 5 A; <0.25 VA for 50:0.025 CTs at 25 A
- Conversion range: 0.02 to 1 × CT primary
- Nominal frequency: 20 to 70 Hz
- Frequency range: 20 to 120 Hz
-
Accuracy:
- ±0.5% of 1 × CT for 5 A CTs
- ±0.5% of 5 × CT for 1 A CTs
- ±0.125 A for 50:0.025 CTs
-
CT (1 A/5 A) withstand:
- 1 second at 80 × rated current
- 2 seconds at 40 × rated current
- Continuous at 3 × rated current
- CT (50:0.025) withstand: Continuous at 150 mA
PHASE CURRENT INPUTS
- CT primary: 1 to 5000 A
- CT secondary: 1 A or 5 A (specify with order)
- Burden: Less than 0.2 VA at rated load
- Conversion range: 0.05 to 20 × CT
- Nominal frequency: 20 to 70 Hz
- Frequency range: 20 to 120 Hz
-
Accuracy:
- At < 2 × CT: ±0.5% of 2 × CT
- At ≥ 2 × CT: ±1% of 20 × CT
-
CT withstand:
- 1 second at 80 × rated current
- 2 seconds at 40 × rated current
- Continuous at 3 × rated current
RTD INPUTS
- 3 wire RTD Types: 100 Ω Platinum (DIN.43760), 100 Ω Nickel, 120 Ω Nickel, 10 Ω Copper
- RTD sensing current: 5 mA
- Isolation: 36 Vpk (isolated with analog inputs and outputs)
- Range: –50 to +250°C
- Accuracy: ±2°C
- Lead resistance: 25 Ω Max per lead for Pt and Ni type; 3 Ω Max per lead for Cu type
- No sensor: >1000 Ω
- Short/low alarm: <–50°C
TRIP COIL SUPERVISION
- Applicable voltage: 20 to 300 V DC / V AC
- Trickle current: 2 to 5 mA
VOLTAGE INPUTS
- VT ratio: 1.00 to 300.00:1 in steps of 0.01
- VT secondary: 273 V AC (full-scale)
- Conversion range: 0.05 to 1.00 × full scale
- Nominal frequency: 20 to 70 Hz
- Frequency range: 20 to 120 Hz
- Accuracy: ±0.5% of full scale
- Max. continuous: 280 V AC
- Burden: >500 kΩ
- Sensor supply: +24 V DC at 20 mA max.
ANALOG CURRENT OUTPUT
- Type: Active
- Range: 4 to 20 mA, 0 to 1 mA (must be specified with order)
- Accuracy: ±1% of full scale
-
Max. load:
- 4 to 20 mA input: 1200 Ω
- 0 to 1 mA input: 10 kΩ
- Isolation: 36 Vpk (isolated with RTDs and analog inputs)
-
4 Assignable Outputs:
- Phase A, B, and C current
- Three-phase average current
- Ground current
- Phase AN (AB), BN (BC), and CN (CA) voltages
- Three-phase average voltage
- Hottest stator RTD
- Hottest bearing RTD
- Hottest other RTD
- RTDs 1 to 12
CASE
- Type: Fully drawout (automatic CT shorts)
- Seal: Seal provision
- Mounting: Panel or 19-inch rack mount
- IP Class: IP40-X
PACKAGING
- Shipping box: 12” × 11” × 10” (W × H × D) / 30.5 cm × 27.9 cm × 25.4 cm
- Shipping weight: 17 lbs Max / 7.7 kg
ENVIRONMENT
- Ambient operating temperature: –40°C to +60°C
- Ambient storage temperature: –40°C to +80°C
- Humidity: Up to 90%, non-condensing
- Altitude: Up to 2000 m
- Pollution degree: 2
| ใบเสนอราคาด่วน | รับราคาพร้อมสถานะสินค้าอย่างรวดเร็วจากทีมบริการลูกค้าของเรา |
|---|---|
| การจัดส่ง | มีบริการจัดส่งด่วน, ขนส่งสินค้า และจัดส่งระหว่างประเทศ |
| สภาพ | ใหม่ 100% พร้อมบรรจุภัณฑ์ดั้งเดิม |
| การชำระเงิน | เรารับบัตร American Express, Discover, MasterCard, PayPal และ Visa เว็บไซต์ของเราปลอดภัยด้วย RapidSSL |
| ท่าเรือขนส่ง | เซี่ยงไฮ้, เซียเหมิน |
| การรับประกัน | 12 เดือน |
| Q: ราคาของเรามีการแข่งขันได้หรือไม่? |
| A: ใช่ เราร่วมมือกับมากกว่า 50 ประเทศทั่วโลก ในฐานะผู้จัดจำหน่ายชั้นนำในจีน เรามอบส่วนลดที่สำคัญตามแนวโน้มตลาด |
| Q: ระยะเวลาการรับประกันคือเท่าไหร่? |
| A: สินค้าใหม่และของแท้ทั้งหมดของเรามาพร้อมกับการรับประกันมาตรฐานหนึ่งปี |
| Q: วิธีการชำระเงินที่เรารับมีอะไรบ้าง? |
| A: เราต้องการชำระเงินเต็มจำนวน 100% ผ่าน T/T (Telegraphic Transfer) ก่อนการจัดส่ง สำหรับสินค้าที่มีระยะเวลาการผลิต ต้องวางเงินมัดจำ 30% ล่วงหน้า และชำระส่วนที่เหลือ 70% ก่อนการจัดส่ง หากคุณมีตัวแทนในจีน คุณสามารถจัดการโอนเงิน RMB ผ่านตัวแทนได้ |
| Q: วิธีการจัดส่งที่เราใช้มีอะไรบ้าง? |
| A: เราใช้บริการจัดส่งหลักๆ ได้แก่ FedEx, DHL, UPS และ BRE หากคุณมีบัญชีกับผู้ให้บริการเหล่านี้ คุณสามารถจัดการการจัดส่งได้โดยตรง เรายังมีบริการจัดส่งฟรีไปยังผู้ส่งสินค้าตั้งอยู่ในประเทศจีน |
| Q: เวลาการจัดส่งของเราคือเท่าไหร่? |
| A: การจัดส่งมักใช้เวลาประมาณ 1-3 วันหลังจากได้รับเงินมัดจำครั้งแรก สำหรับสินค้าที่มีระยะเวลาการผลิต การจัดส่งจะเป็นไปตามตารางเวลาที่กำหนด |
| Q: เราบรรจุสินค้ายังไง? |
| A: เรารับประกันการบรรจุภัณฑ์ที่ปลอดภัยด้วยชั้นป้องกันหลายชั้น สินค้าจะถูกใส่ในกล่องเดิมและปิดผนึกด้วยสติ๊กเกอร์ จากนั้นจะมีการห่อด้วยฟองอากาศเพื่อป้องกันการกระแทกระหว่างการขนส่ง สุดท้ายสินค้าจะถูกบรรจุอย่างแน่นหนาในกล่องที่ทนทาน |
| Q: ลูกค้าสามารถติดต่อเราและขอใบเสนอราคาได้อย่างไร? |
| A: คุณสามารถติดต่อเราผ่านทางอีเมล, WhatsApp, WeChat, Skype หรือแพลตฟอร์มการสื่อสารที่คุณชื่นชอบ ติดต่อเราพร้อมแจ้งความต้องการของคุณ และเราจะให้ใบเสนอราคาที่รวดเร็วและปรับแต่งเฉพาะสำหรับคุณ |