The HIMA F35 safety-related controller is a compact system housed in a metal enclosure. It features 24 digital inputs, 8 digital outputs, 2 counters, and 8 analog inputs.


Configuration

  • Programming Tool:
    • ELOP II Factory: Required for operating system versions prior to 7.
    • SILworX: Required for operating system version 7 and beyond.

General

  • User Memory:

    • Versions prior to 6.46:
      • max. 500 kB user program
      • max. 500 kB user data
    • Version 6.100:
      • max. 2047 kB user program
      • max. 2047 kB user data
    • Version 7:
      • max. 1023 kB user program
      • max. 1023 kB user data
  • Response Time: ≥ 20 ms

  • Interfaces:

    • Ethernet
    • PROFIBUS DP master/slave
    • Modbus master/slave
    • INTERBUS Master
    • RS485 (Modbus M&S)
    • 4 x RJ-45, 10/100BaseT (with 100 Mbit/s) with integrated switch
    • D-sub connector, 9 poles (FB1, FBs)
    • D-sub connector, 9 poles (FB3)
  • Operating Voltage: 24 VDC, -15 %...+20 %, wss ≤ 15 %, from a power supply unit with safe insulation in accordance with IEC 61131-2

  • Current Input: max. 9 A (with maximum load), Idle: 0.5 A

  • Fuse (External): 10 A time-lag (T)

  • Buffer for Date/Time: Gold capacitor

  • Temperature Class: T4 (Zone 2)

  • Operating Temperature: 0 °C...+60 °C

  • Storage Temperature: -40 °C...+85 °C

  • Type of Protection: IP20

  • Max. Dimensions (without plug):

    • Width: 257 mm (with enclosure screws)
    • Height: 114 mm (with fixing bolt)
    • Depth: 97 mm (with earthing screw)
  • Weight: approx. 1.2 kg


Digital Inputs

  • Number of Inputs: 24 (non-galvanically isolated)
  • Type of Input: Current sinking logic, 24 V, type 1 in accordance with IEC 61131-2
  • High Level: Voltage - 15 V (default value 13 V + 2 V, safety range can be configured up to 30 VDC), Current input - approx. 3.5 mA at 24 VDC, approx. 4.5 mA at 30 VDC
  • Low Level: Voltage - max. 5 V DC (default value 7 V - 2 V, safety distance can be freely configured up to max. high level of -4 V and min. 2 V), Current input - max. 1.5 mA (1 mA at 5 V)
  • Input Resistance: < 7 kΩ
  • Overvoltage Protection: - 10 V, +35 V
  • Max. Wire Length: 300 m
  • Supply: 3 x 20 V / 100 mA, short-circuit-proof
  • Measurement Accuracy at 25 °C, max.: ±0.2 % of final value
  • Measurement Accuracy on Full Temperature Range, max.: ±1 % of final value
  • Temperature Coefficient, max.: ±0.023 %/K of final value

Analog Inputs

  • Number of Inputs: 8 (unipolar, non-galvanically isolated)
  • External Shunt Adapter for Current Measurement: Z 7301 (250 Ω), Z 7302 (500 Ω)
  • Nominal Range: 0...+10 VDC, 0...+20 mA with shunt 500 Ω
  • Operating Range: -0.1...+11.5 VDC, -0.4...+23 mA with 500 Ω shunt
  • Input Resistance: 1 MΩ
  • Input Line Max.: 300 m, shielded, twisted pairs of wires
  • Internal Resistance of the Signal Source: ≤ 500 Ω
  • Digital Resolution: 12 bit
  • Measurement Accuracy at 25 °C, max.: ± 0.1 % of final value
  • Measurement Accuracy on Full Temperature Range, max.: ± 0.5 % of final value
  • Temperature Coefficient, max.: ±0.011 %/K of full scale
  • Safety-Related Accuracy, max.: ± 2 % of final value
  • Measured Value Refresh: once per cycle of the controller
  • Sampling Time: approx. 45 µs
  • Transmitter Supplies: 8 x 24...28 V / ≤ 46 mA, short-circuit-proof

Digital Outputs

  • Number of Outputs: 8 (non-galvanically isolated, common ground L-)
  • Output Voltage: L+ minus 2 V
  • Output Current:
    • Channels 1...3 and 5...7: 0.5 A at 60 °C
    • Channels 4 and 8: 1 A at 60 °C (2 A at 50 °C)
  • Minimum Load: 2 mA for each channel
  • Internal Voltage Drop: max. 2 V at 2 A
  • Leakage Current (with Low Level): max. 1 mA at 2 V
  • Behavior with Overload: The affected output is switched off and cyclically switched on again
  • Total Output Current: max. 7 A; upon overload, all outputs are switched off and cyclically switched on again

Counter

  • Number of Counters: 2 (non-galvanically isolated)

  • Inputs: 3 on each (A, B, Z)

  • Input Voltages:

    • High level (5 V): 4...6 V
    • High level (24 V): 13...33 V
    • Low level (5 V): 0...0.5 V
    • Low level (24 V): -3...5 V
  • Input Currents: 1.4 mA at 5 V, 6.5 mA at 24 V

  • Input Impedance: 3.7 kΩ

  • Input Line Max.: 500 m, shielded, twisted pairs of wires

  • Counter Resolution: 24 bit

  • Min. Pulse Length: 5 µs

  • Max. Input Frequency: 100 kHz (at 5 V and 24 V input voltage)

  • Triggered on: negative edge

  • Edge Steepness: 1 V/µs

  • Pulse Duty Factor: 1 : 1 (for 100 kHz)


Environmental Requirements

  • Protection Class: Protection class III in accordance with IEC/EN 61131-2
  • Ambient Temperature: 0...+60 °C
  • Storage Temperature: -40...+85 °C
  • Pollution: Pollution degree II in accordance with IEC/EN 61131-2
  • Altitude: < 2000 m
  • Housing: Standard: IP20
  • Supply Voltage: 24 VDC
ใบเสนอราคาด่วน รับราคาพร้อมสถานะสินค้าอย่างรวดเร็วจากทีมบริการลูกค้าของเรา
การจัดส่ง มีบริการจัดส่งด่วน, ขนส่งสินค้า และจัดส่งระหว่างประเทศ
สภาพ ใหม่ 100% พร้อมบรรจุภัณฑ์ดั้งเดิม
การชำระเงิน เรารับบัตร American Express, Discover, MasterCard, PayPal และ Visa เว็บไซต์ของเราปลอดภัยด้วย RapidSSL
ท่าเรือขนส่ง เซี่ยงไฮ้, เซียเหมิน
การรับประกัน 12 เดือน
Q: ราคาของเรามีการแข่งขันได้หรือไม่?
A: ใช่ เราร่วมมือกับมากกว่า 50 ประเทศทั่วโลก ในฐานะผู้จัดจำหน่ายชั้นนำในจีน เรามอบส่วนลดที่สำคัญตามแนวโน้มตลาด
Q: ระยะเวลาการรับประกันคือเท่าไหร่?
A: สินค้าใหม่และของแท้ทั้งหมดของเรามาพร้อมกับการรับประกันมาตรฐานหนึ่งปี
Q: วิธีการชำระเงินที่เรารับมีอะไรบ้าง?
A: เราต้องการชำระเงินเต็มจำนวน 100% ผ่าน T/T (Telegraphic Transfer) ก่อนการจัดส่ง สำหรับสินค้าที่มีระยะเวลาการผลิต ต้องวางเงินมัดจำ 30% ล่วงหน้า และชำระส่วนที่เหลือ 70% ก่อนการจัดส่ง หากคุณมีตัวแทนในจีน คุณสามารถจัดการโอนเงิน RMB ผ่านตัวแทนได้
Q: วิธีการจัดส่งที่เราใช้มีอะไรบ้าง?
A: เราใช้บริการจัดส่งหลักๆ ได้แก่ FedEx, DHL, UPS และ BRE หากคุณมีบัญชีกับผู้ให้บริการเหล่านี้ คุณสามารถจัดการการจัดส่งได้โดยตรง เรายังมีบริการจัดส่งฟรีไปยังผู้ส่งสินค้าตั้งอยู่ในประเทศจีน
Q: เวลาการจัดส่งของเราคือเท่าไหร่?
A: การจัดส่งมักใช้เวลาประมาณ 1-3 วันหลังจากได้รับเงินมัดจำครั้งแรก สำหรับสินค้าที่มีระยะเวลาการผลิต การจัดส่งจะเป็นไปตามตารางเวลาที่กำหนด
Q: เราบรรจุสินค้ายังไง?
A: เรารับประกันการบรรจุภัณฑ์ที่ปลอดภัยด้วยชั้นป้องกันหลายชั้น สินค้าจะถูกใส่ในกล่องเดิมและปิดผนึกด้วยสติ๊กเกอร์ จากนั้นจะมีการห่อด้วยฟองอากาศเพื่อป้องกันการกระแทกระหว่างการขนส่ง สุดท้ายสินค้าจะถูกบรรจุอย่างแน่นหนาในกล่องที่ทนทาน
Q: ลูกค้าสามารถติดต่อเราและขอใบเสนอราคาได้อย่างไร?
A: คุณสามารถติดต่อเราผ่านทางอีเมล, WhatsApp, WeChat, Skype หรือแพลตฟอร์มการสื่อสารที่คุณชื่นชอบ ติดต่อเราพร้อมแจ้งความต้องการของคุณ และเราจะให้ใบเสนอราคาที่รวดเร็วและปรับแต่งเฉพาะสำหรับคุณ
 

ดูล่าสุด

Express Shipping icon
จัดส่งด่วน
จัดส่งรวดเร็วสำหรับความต้องการเร่งด่วนของคุณ
Large stock icon
สินค้าคงคลังจำนวนมาก
สต็อกจำนวนมากพร้อมจัดส่งทันที
Quality Assurance Icon
การประกันคุณภาพ
ชิ้นส่วน PLC & DCS แท้คุณภาพสูงระดับพรีเมียม
Global Service icon
บริการทั่วโลก
สนับสนุนลูกค้าทั่วโลกด้วยบริการที่เชื่อถือได้