{"product_id":"aip602-yokogawa-cabinet-door-fan-cooling-unit","title":"AIP602 Yokogawa Cabinet Door Fan Cooling Unit","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAIP602\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eheavy-duty door-mounted cooling fan unit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for Yokogawa control cabinets, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eactive heat dissipation and airflow\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor high-density I\/O modules and processors, preventing thermal buildup that can reduce system reliability and accuracy.\u003c\/p\u003e\n\u003cp\u003eBuilt for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous 24\/7 industrial operation\u003c\/strong\u003e, the AIP602 features a robust axial fan, high-grade bearings, and a durable metal frame. When used with cabinet filters, it maintains a clean, pressurized environment inside the enclosure, ensuring optimal performance of sensitive electronics.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eDoor-mounted cooling fan unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa RIO\/FIO cabinets and console assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC or 220–240 V AC (region-specific)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan Type\u003c\/td\u003e\n\u003ctd\u003eAxial flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eMetal frame with high-durability fan blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eIntegrated into cabinet door\/panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eHeat dissipation and air circulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003eContinuous industrial operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance\u003c\/td\u003e\n\u003ctd\u003eSupports replaceable filter media (depending on grill assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYokogawa Field Control Stations (FCS) and marshaling cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-climate-controlled industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical for maintaining operating temperatures of high-density modules such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI141\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAV141\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommonly replaced during preventative maintenance cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: When should the AIP602 fan unit be replaced?\u003c\/strong\u003e\u003cbr\u003eA: Inspect annually. Replace immediately if there is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eincreased noise (bearing wear)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereduced airflow\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent I\/O modules from exceeding safe temperature limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this unit include an external finger guard?\u003c\/strong\u003e\u003cbr\u003eA: The AIP602 includes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efan and motor assembly only\u003c\/strong\u003e. The decorative grill and dust filter may need to be ordered separately if not included in the original spare kit.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51707406123320,"sku":"AIP602","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AIP6021.jpg?v=1770256782","url":"https:\/\/www.automodulexpert.com\/tr\/products\/aip602-yokogawa-cabinet-door-fan-cooling-unit","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}