{"product_id":"air-filter-module-yokogawa-t9070ck","title":"Air Filter Module Yokogawa T9070CK","description":"\u003ch2\u003eTechnical Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT9070CK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodular high-efficiency air filtration assembly\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDCS cabinets. It protects internal electronics—such as CPUs and I\/O modules—by filtering dust and corrosive particulates from the cooling airflow. Its modular design allows for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003equick maintenance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand replacement of the filter media without tools, ensuring uninterrupted cabinet thermal management.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDetailed Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Efficiency Air Filtration Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eT9070CK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eParticulate mitigation for cabinet thermal management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia Material\u003c\/td\u003e\n\u003ctd\u003eElectrostatic or multi-layered synthetic fiber (high-capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +55°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003eSuitable for high-humidity industrial environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa 19-inch racks and specialized RIE enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Application\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS 3000, ProSafe-RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Format\u003c\/td\u003e\n\u003ctd\u003ePanel or enclosure-mount with quick-release fasteners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Requirement\u003c\/td\u003e\n\u003ctd\u003eReplaceable filter element within permanent module frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Protection and Maintenance\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 environmental rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby filtering insulating dust and corrosive moisture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrevents buildup on heat sinks and backplanes, ensuring stable thermal performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModular design allows\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erapid media replacement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout specialized tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimizes downtime and technician exposure to cabinet heat\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between T9070CB and T9070CK?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT9070CB:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual filter sheet or fan-specific filter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT9070CK:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModular, high-capacity assembly for intake\/exhaust panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module include cooling fans?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNo. The T9070CK is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efilter module only\u003c\/strong\u003e. Fans (e.g., AIP series) are separate part numbers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCan the T9070CK be used in outdoor cabinets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esheltered industrial enclosures\u003c\/strong\u003e. For outdoor use, it must be behind a louver or weather shield to prevent water ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51775887737144,"sku":"T9070CK","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/T9070CB1.jpg?v=1770774574","url":"https:\/\/www.automodulexpert.com\/tr\/products\/air-filter-module-yokogawa-t9070ck","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}