{"product_id":"anr10d-420-yokogawa-bus-node-interface-unit","title":"ANR10D-420 Yokogawa Bus Node Interface Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANR10D-420\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Node Interface Unit (NIU) developed by Yokogawa Electric Corporation for the CENTUM VP Distributed Control System.\u003c\/p\u003e\n\u003cp\u003eServing as a communication bridge between Field Control Units (FCUs) and remote I\/O modules, the ANR10D-420 operates over a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant ER Bus (Extended Remote Bus)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture. With support for redundant power supplies and communication paths, it ensures continuous transmission of analog and digital field signals—even in the event of a single component failure. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e19-inch rack-mountable design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables high-density I\/O deployment in control rooms and marshaling cabinets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eANR10D-420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ FIO (Field Network I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Dual-Redundant ER Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration (-4)\u003c\/td\u003e\n\u003ctd\u003eSupports dual-redundant power supply modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (-2)\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection (-0)\u003c\/td\u003e\n\u003ctd\u003eBasic type (no explosion protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 I\/O modules per node\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 230 VA \/ 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSeamless failover for power and ER bus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 mm × 221.5 mm × 21.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Communication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnects to FCUs via ER Bus Interface Master Module (e.g., EB401)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to 14 remote nodes per FCU (depending on database license such as \/NDEL option)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTypical data refresh cycle:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u0026lt; 1 second\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor standard variables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for scalable architectures across large industrial facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables distributed control topology while maintaining high-speed, deterministic communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale oil refineries and petrochemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical processing sites\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote I\/O expansion for distributed plant layouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-availability systems requiring redundant communication paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat modules fit into the ANR10D-420?\u003c\/strong\u003e\u003cbr\u003eThe chassis supports Yokogawa FIO modules, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAAI Series (Analog I\/O modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eADV Series (Digital I\/O modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpecialized communication modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be used in hazardous areas?\u003c\/strong\u003e\u003cbr\u003eThe “-0” suffix indicates a basic version without explosion protection. For hazardous environments, versions with Type n or FM Non-Incendive certifications should be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes. I\/O modules installed within the ANR10D-420 can generally be replaced while the system remains powered and operational, provided the configuration supports hot-swapping.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51796681621816,"sku":"ANR10D-420","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ANR10D-4201.jpg?v=1770966548","url":"https:\/\/www.automodulexpert.com\/tr\/products\/anr10d-420-yokogawa-bus-node-interface-unit","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}