{"product_id":"digital-input-module-yokogawa-adv151-e63-d5a00","title":"Digital Input Module Yokogawa ADV151-E63\/D5A00","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV151-E63\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32-channel high-performance digital input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Integrated Production Control System\u003c\/strong\u003e. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 V DC logic\u003c\/strong\u003e, compatible with both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esink and source input configurations\u003c\/strong\u003e, enabling flexible integration with various field devices like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elimit switches, proximity sensors, and auxiliary contacts\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE63 variant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical environments\u003c\/strong\u003e, featuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3-compliant corrosion protection\u003c\/strong\u003e, an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated LED status display\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epre-installed D5A00 KS-cable adapter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor efficient high-density wiring. It is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eextended temperature operation (-20°C to +70°C)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand maintains robust isolation for signal integrity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV151-E63\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 Isolated Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD5A00 (Integrated KS Cable Adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e107.5 × 130 × 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LED display provides immediate feedback on channel status for troubleshooting and commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Corrosion Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures reliable operation in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esulfurous or corrosive atmospheres\u003c\/strong\u003e, typical of chemical plants, refineries, and offshore facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePre-installed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eD5A00 adapter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows single KS multi-core cable connection, reducing wiring time and cabinet complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProtects the master controller from ground loops and electrical surges, ensuring plant-wide stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOffshore and Petrochemical Platforms:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring switches and sensors in harsh, corrosive environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRefineries \u0026amp; Chemical Plants:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAcquiring signals from valves, pumps, and other discrete devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Control Cabinets:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSimplifying field signal marshalling via KS-cable connectivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used with older CENTUM CS 3000 systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebackward compatible\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith CENTUM CS 3000 when used with appropriate node units (ANB or ANT).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module suitable for high-speed pulse counting?\u003c\/strong\u003e\u003cbr\u003eA: The response time is 8 ms. For\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed encoders or flow meters\u003c\/strong\u003e, a dedicated ADV151-P series pulse input module is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the advantage of isolated channels?\u003c\/strong\u003e\u003cbr\u003eA: Each channel is electrically isolated, preventing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esurges or ground loops\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom damaging the master controller, ensuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eplant-wide system stability\u003c\/strong\u003e.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51688081326392,"sku":"ADV151-E63\/D5A00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV151-E10.jpg?v=1770088644","url":"https:\/\/www.automodulexpert.com\/tr\/products\/digital-input-module-yokogawa-adv151-e63-d5a00","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}