{"product_id":"digital-input-module-yokogawa-adv157-s00","title":"Digital Input Module Yokogawa ADV157-S00","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV157-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density 32-channel digital input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Integrated Production Control System\u003c\/strong\u003e. As part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO (Field network I\/O)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily, this module provides reliable acquisition of discrete signals from field devices such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evalve positions, motor feedback contacts, and pressure switches\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eOperating at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 V DC\u003c\/strong\u003e, the ADV157-S00 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eboth sink and source input configurations\u003c\/strong\u003e, offering compatibility with a wide range of industrial sensors. Its robust design features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 kV AC isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween field signals and the system backplane, ensuring protection against electrical noise, ground loops, and transient surges. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-S00 suffix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates a standard-type module suitable for general-purpose automation applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV157\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-S00 (Standard Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Logic Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (Sink\/Source compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ON Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.0 – 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput OFF Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 5.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 mA ±20% per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (Signal to System logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommoning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 channels per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (standard S\/P type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Power Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA max at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eFunctional Capabilities\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 inputs per module maximize I\/O density and minimize node unit footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports potential-free contacts (dry contacts) and voltage-generating sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProtects the DCS backplane against field-side transients and surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy-Ready:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan be configured in dual-redundant FIO nests for uninterrupted input acquisition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCaptures status signals from pumps, valves, and limit switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Control Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigured in redundant FIO nests to ensure continuous operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMarshalled Panels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfaces via pressure-clamp terminal blocks or KS multi-core cables to external I\/O panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the ADV157 differ from the ADV151?\u003c\/strong\u003e\u003cbr\u003eA: Both are 32-channel modules, but the ADV157 is often used in specific node configurations or firmware revisions. Check ANB\/ANT compatibility before deployment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used in a redundant pair?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports dual-redundancy in a redundant FIO nest.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How are the inputs wired?\u003c\/strong\u003e\u003cbr\u003eA: Wiring is typically done via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure-clamp terminal blocks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS multi-core cables\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto an external marshalling panel, depending on the base unit used.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51688110981432,"sku":"ADV157-S00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV157-S00.jpg?v=1770083113","url":"https:\/\/www.automodulexpert.com\/tr\/products\/digital-input-module-yokogawa-adv157-s00","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}