{"product_id":"nfat141-s01-analog-input-module-yokogawa","title":"NFAT141-S01 Analog Input Module Yokogawa","description":"\u003ch3\u003eTechnical Functional Summary\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAT141-S01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density analog voltage input module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa STARDOM FCN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautonomous controller series. It is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel voltage signal acquisition\u003c\/strong\u003e, commonly used with analytical instruments and specialized transmitters providing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1–5 V DC output signals\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-bit high-resolution data conversion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand fast refresh cycles for accurate process monitoring in applications such as oil and gas upstream operations, water treatment facilities, and power generation systems.\u003c\/p\u003e\n\u003cp\u003eUnlike fully isolated multi-channel designs, the NFAT141-S01 uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommon-ground channel architecture\u003c\/strong\u003e, making it a cost-effective solution for centralized control cabinet installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Engineering Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Voltage Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFAT141-S01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e1–5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e≥ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Refresh Cycle\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1.5 kV AC (between inputs and system logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 450 mA @ 5 V DC (backplane powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eSystem Application Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density voltage signal monitoring from analytical equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutonomous process control in FCN-500 and FCN-RTU systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant data acquisition architectures in critical process loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is NFAT141-S01 different from NFAI141?\u003c\/strong\u003e\u003cbr\u003eNFAT141-S01 is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage inputs (1–5 V)\u003c\/strong\u003e, while NFAI141 is typically used for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent inputs (4–20 mA)\u003c\/strong\u003e. The S01 suffix indicates hardware revision compatibility with newer FCN backplanes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it directly measure 4–20 mA signals?\u003c\/strong\u003e\u003cbr\u003eNo. A 250 Ω precision shunt resistor must be used to convert current signals into voltage signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs channel isolation provided?\u003c\/strong\u003e\u003cbr\u003eNo. Isolation is provided between field inputs and system logic only. For applications requiring full channel isolation, modules such as NFAI143 are recommended.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51821137789240,"sku":"NFAT-141-S01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFAT-141-S01.jpg?v=1771983537","url":"https:\/\/www.automodulexpert.com\/tr\/products\/nfat141-s01-analog-input-module-yokogawa","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}