{"product_id":"pw482-50-s2-yokogawa-power-supply-centum-vp-power-module","title":"PW482-50 S2  Yokogawa Power Supply CENTUM VP Power Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW482-50 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a mission-critical\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower supply module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Distributed Control System (DCS)\u003c\/strong\u003e. It provides stable, regulated DC power to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Unit (FCU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecomponents, ensuring reliable processor operation and accurate I\/O signal processing.\u003c\/p\u003e\n\u003cp\u003eEngineered for harsh industrial environments, the PW482-50 S2 incorporates advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enoise filtering and surge suppression\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect sensitive control electronics. As a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStyle S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erevision, it features an enhanced hardware design optimized for improved thermal stability and long-term reliability in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24\/7 continuous process operations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePW482-50 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Power Supply Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP Field Control Units (AFV series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC or 220–240 V AC (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardized DC bus for FCU backplanes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1+1 parallel redundancy supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower-fail status contacts to DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConvection or forced air (enclosure dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 cm × 20.3 cm × 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStyle Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eSystem Integration \u0026amp; Reliability\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Operation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn duplex configurations, two PW482-50 S2 units share the load; if one fails, the remaining unit instantly assumes full load without system reset\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Visibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LED indicators provide clear\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePower OK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFault\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estatus at a glance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated filtering and surge protection safeguard CPUs and I\/O modules from electrical disturbances\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManufactured to strict industrial quality standards for long-term cabinet operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the “-50” designation indicate?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix typically refers to a specific input voltage\/frequency configuration compatible with standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50\/60 Hz industrial power grids\u003c\/strong\u003e, supporting global deployment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould redundant power supplies use the same Style Code?\u003c\/strong\u003e\u003cbr\u003eYes. For proper load sharing, mechanical fit, and thermal behavior, it is strongly recommended to use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eidentical modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., two PW482-50 S2 units) in redundant power configurations.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51638622388536,"sku":"PW482-50 S2","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PW482-50_S2.jpg?v=1769047563","url":"https:\/\/www.automodulexpert.com\/tr\/products\/pw482-50-s2-yokogawa-power-supply-centum-vp-power-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}