{"product_id":"sb401-10-s1-yokogawa-esb-bus-slave-module-centum-vp","title":"SB401-10 S1 Yokogawa ESB Bus Slave Module CENTUM VP","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSB401-10 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed communication slave module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Distributed Control System (DCS)\u003c\/strong\u003e. It serves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einterface for an I\/O node\u003c\/strong\u003e, enabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time data exchange\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween remote I\/O units and a Field Control Station (FCS) via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExtended Serial Backplane (ESB) bus\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eDesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability industrial environments\u003c\/strong\u003e, the S1 revision ensures long-term stability and deterministic performance. Its modular form factor allows seamless integration into node interface units, providing a robust backbone for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed process control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross large plant installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eSB401-10 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eESB Bus Interface Slave Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Bus Compatibility\u003c\/td\u003e\n\u003ctd\u003eExtended Serial Backplane (ESB) Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Speed\u003c\/td\u003e\n\u003ctd\u003eHigh-speed serial communication for real-time I\/O updates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eCompatible with redundant ESB bus configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Mounting\u003c\/td\u003e\n\u003ctd\u003eDedicated slots in I\/O node units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eDraws from internal node backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Dimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e13.0 cm × 3.2 cm × 10.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Tolerance\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade vibration and thermal resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed I\/O Expansion\u003c\/strong\u003e\u003cbr\u003eConnecting remote I\/O racks to a central FCS for field device management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Process Control\u003c\/strong\u003e\u003cbr\u003eLinking multiple analog and digital modules in power generation or petrochemical plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Redundancy Upgrades\u003c\/strong\u003e\u003cbr\u003eDual-module deployment ensures zero data loss during single-bus failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"Slave\" designation mean?\u003c\/strong\u003e\u003cbr\u003eA: The slave module resides in the I\/O node and receives instructions from the master interface card in the FCS, ensuring coordinated data flow across local and remote racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with the ER Bus?\u003c\/strong\u003e\u003cbr\u003eA: No. The SB401-10 S1 is specifically designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESB Bus\u003c\/strong\u003e. Systems using the ER Bus require a different interface module (e.g., EB series).\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51718623789368,"sku":"SB401-10 S1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/SB401-10_S11.jpg?v=1770344676","url":"https:\/\/www.automodulexpert.com\/tr\/products\/sb401-10-s1-yokogawa-esb-bus-slave-module-centum-vp","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}