{"product_id":"vnet-ip-plc-coupler-module-yokogawa-aip503","title":"Vnet\/IP PLC Coupler Module Yokogawa AIP503","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AIP503\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP interface coupler module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to integrate third-party\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLCs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol networks. Acting as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed communication gateway\u003c\/strong\u003e, the AIP503 enables seamless data exchange between external subsystems and the Yokogawa DCS, supporting both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommand and monitoring functions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEngineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability architectures\u003c\/strong\u003e, the module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic data transfer\u003c\/strong\u003e, protocol conversion, and galvanic isolation to ensure the integrity of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP real-time bus\u003c\/strong\u003e. Its robust industrial design supports continuous operation in demanding environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIP503\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eBus Coupler \/ Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP (Gigabit Ethernet physical layer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Speed\u003c\/td\u003e\n\u003ctd\u003e1 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP network ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between system bus and field network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 V DC @ 0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eStandard slot in PLC interface unit or system cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Application\u003c\/h2\u003e\n\u003cp\u003eThe AIP503 is essential in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex industrial facilities\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere diverse control platforms must interoperate. Typical applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLinking package control systems (compressors, turbines, chillers) to central\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMI\/OTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erefineries, petrochemical plants, and power generation facilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration of specialized subsystems into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP or CS 3000 DCS environment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AIP503 support redundant network paths?\u003c\/strong\u003e\u003cbr\u003eYes. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual network ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallow integration into a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant Vnet\/IP topology\u003c\/strong\u003e, maintaining continuous communication if one path fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the AIP503 compatible with older V-net systems?\u003c\/strong\u003e\u003cbr\u003eNo. The AIP503 is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP (Ethernet-based)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetworks. Legacy coaxial V-net systems require a different coupler or bridging solution.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51746751283512,"sku":"AIP503","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AIP503.jpg?v=1770603239","url":"https:\/\/www.automodulexpert.com\/tr\/products\/vnet-ip-plc-coupler-module-yokogawa-aip503","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}