{"product_id":"yokogawa-aai835-centum-vp-analog-i-o-module","title":"YOKOGAWA AAI835 CENTUM VP Analog I\/O Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI835-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehybrid analog interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Distributed Control System\u003c\/strong\u003e. This single-slot module integrates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 analog input channels and 4 analog output channels\u003c\/strong\u003e, providing both sensing and actuation capabilities in a compact form factor.\u003c\/p\u003e\n\u003cp\u003eFully isolated channels ensure that field-side electrical noise or faults are contained, maintaining the integrity of the overall DCS network. Its hybrid design is particularly suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote nodes or auxiliary control loops\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere space efficiency and multi-functionality are important.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHybrid Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-channel 4–20 mA input + 4-channel 4–20 mA output in one unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel is electrically isolated for superior protection against ground loops and EMI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Industrial Build:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eS50 configuration denotes a general-purpose, non-explosion-protected module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Interfacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports pressure clamp terminals, MIL connectors, or KS1 cables for rapid deployment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAAI835\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 × 10.7 × 13 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cp\u003eThe AAI835-S50 is ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elocalized process control units\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePump stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall-scale chemical reactors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtility skids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy combining both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einput monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., pressure, flow) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutput control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., valve actuation) in a single module, it simplifies the architecture of auxiliary control loops within larger plant networks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AAI835-S50 be used in redundant configurations?\u003c\/strong\u003e\u003cbr\u003eA: Typically, this module is used in non-redundant applications for cost-effective localized control. For mission-critical loops requiring full failover, separate dedicated input and output modules are recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What cable is required for the MIL connector interface?\u003c\/strong\u003e\u003cbr\u003eA: The MIL connector option is typically paired with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS1 dedicated cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor direct connection to Yokogawa terminal boards or signal conditioners.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51662141358392,"sku":"AAI835","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAI8351.jpg?v=1769391860","url":"https:\/\/www.automodulexpert.com\/tr\/products\/yokogawa-aai835-centum-vp-analog-i-o-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}