{"product_id":"yokogawa-adm51c-relay-contact-output-module","title":"Yokogawa ADM51C Relay Contact Output Module","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADM51C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density relay-style contact output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Yokogawa DCS systems (CENTUM VP and CS 3000). It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 discrete dry-contact outputs\u003c\/strong\u003e, organized in two isolated groups of eight channels. The module is used for controlling external devices such as solenoid valves, alarm signals, or interposing relays. It ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic performance\u003c\/strong\u003e, high electrical isolation, and reliability suitable for continuous process control.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eItem\u003c\/th\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eContact Output Module (Relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eADM51C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 channels, isolated in 2 groups of 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDry contact (No power supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Ratings\u003c\/td\u003e\n\u003ctd\u003e30 V DC, 2 A; 125 V AC, 0.4 A; 250 V AC, 0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2300 V AC (output-to-system); 1000 V AC (channel-to-channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eMax 10 ms (at rated load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd\u003e20 million operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Life\u003c\/td\u003e\n\u003ctd\u003e100,000 operations (at rated load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 V DC, 350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Compatibility\u003c\/td\u003e\n\u003ctd\u003eANB10S, ANB10D, ANT10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical relay outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide clean isolation for field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo isolated groups of 8 channels protect the system from electrical faults in any single group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDry-contact design allows connection to a wide variety of voltage levels and signal types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for triggering low-power solenoids, alarms, or relays; not for direct high-power motor loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the ADM51C drive high-power AC motors directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNo. It is intended to trigger interposing relays or low-power loads. High-power motors require separate motor starters or contactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the high withstanding voltage important?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtects the DCS backplane from field-side voltage surges or spikes, enhancing system resilience.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYes, in a redundant Yokogawa FIO node configuration, it can be replaced while the system is running, following plant safety procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51776121733432,"sku":"ADM51C","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADM51C.jpg?v=1770774573","url":"https:\/\/www.automodulexpert.com\/tr\/products\/yokogawa-adm51c-relay-contact-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}