{"product_id":"yokogawa-aea4d-05-analog-terminal-board","title":"Yokogawa AEA4D-05  Analog Terminal Board","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AEA4D-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density analog terminal board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control systems (DCS). Serving as a centralized hub for field wiring, it consolidates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 analog input and output channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand interfaces with system I\/O modules via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated KS1 multi-core cables\u003c\/strong\u003e. The AEA4D-05 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle and dual-redundant configurations\u003c\/strong\u003e, ensuring maximum process uptime. Its robust design, standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM4 screw terminals\u003c\/strong\u003e, and noise-immune signal path make it a reliable choice for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower, chemical, and oil \u0026amp; gas industries\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Suffix\u003c\/td\u003e\n\u003ctd\u003eAEA4D-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eSupports single and dual-redundant I\/O module configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection (-0)\u003c\/td\u003e\n\u003ctd\u003eStandard type (without surge absorber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection (-5)\u003c\/td\u003e\n\u003ctd\u003eBasic type (no explosion protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Cable\u003c\/td\u003e\n\u003ctd\u003eDedicated KS1 Multi-core Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eM4 Screw Terminals (8 points × 2 rows)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e≥ 100 MΩ (at 500 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch Rack Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA4D-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emarshalling cabinets\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto organize and consolidate field signals before they enter the control station. It interfaces with a broad range of Yokogawa analog I\/O modules:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Modules:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAAI135, AAI141, AAI143, AAV141, AAV144, AAP135\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Modules:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAAI543, AAV542, AAV544\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMixed I\/O Modules:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAAI835, AAI841, AAB841\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is ideal for process loops in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil \u0026amp; gas, chemical, and power generation facilities\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere signal reliability and redundancy are critical.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between AEA4D and AEA3D?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA4D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 channels\u003c\/strong\u003e, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA3D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-channel board\u003c\/strong\u003e, typically used for 2-wire transmitter applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this board for thermocouple signals?\u003c\/strong\u003e\u003cbr\u003eNo. For thermocouple inputs, use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAET4D terminal board\u003c\/strong\u003e, which includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecold-junction compensation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the KS1 cable included?\u003c\/strong\u003e\u003cbr\u003eNo. The KS1 cable is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eseparate accessory\u003c\/strong\u003e. Specify the required length (e.g., KS1-10 for 10 meters) according to the distance between the terminal board and the I\/O rack.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51747076702520,"sku":"AEA4D-05","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AEA4D-05.jpg?v=1770603239","url":"https:\/\/www.automodulexpert.com\/tr\/products\/yokogawa-aea4d-05-analog-terminal-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}