{"product_id":"yokogawa-nfai141-h00-ccc01-analog-input-module","title":"Yokogawa NFAI141-H00\/CCC01 Analog Input Module","description":"\u003ch2\u003eTechnical Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAI141-H00\/CCC01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density analog input module with HART communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP DCS\u003c\/strong\u003e. It serves as the primary interface for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA field transmitter signals\u003c\/strong\u003e, enabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time process variable acquisition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediagnostic data transfer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom smart instruments to the control system.\u003c\/p\u003e\n\u003cp\u003eWith the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CCC01 conformal coating\u003c\/strong\u003e, this module is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eharsh industrial environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring G3 corrosive gas resistance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDetailed Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003eNFAI141-H00\/CCC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eProtocol versions 5, 6, 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Cycle\u003c\/td\u003e\n\u003ctd\u003e10 ms for 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ω typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eConformal coating (CCC01, G3 corrosive gas resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 250 mA (internal); 24 VDC, 450 mA (field)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Environmental Resilience\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/CCC01\u003c\/strong\u003e: Conformal coating for harsh, corrosive atmospheres (G3 standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH00\u003c\/strong\u003e: Standard interface for pressure clamp terminal blocks, ensuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical reliability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evibration resistance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePowers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-wire transmitters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhile supporting 4-wire externally powered devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodule-level isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect system electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide transmitter power?\u003c\/strong\u003e\u003cbr\u003eYes. Internal 24 VDC field-side supply powers 2-wire transmitters; 4-wire transmitters are supported with external power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does HART communication benefit operations?\u003c\/strong\u003e\u003cbr\u003eAllows access to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edevice health and secondary variables\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., sensor temperature, totalized flow) over the same 4–20 mA loop without extra wiring, supporting predictive maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre channels individually isolated?\u003c\/strong\u003e\u003cbr\u003eNo. Channels share a common ground. For\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efull channel-to-channel isolation\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAI143 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis recommended.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51775860080952,"sku":"NFAI141-H00\/CCC01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFAI141-S00.jpg?v=1729234443","url":"https:\/\/www.automodulexpert.com\/tr\/products\/yokogawa-nfai141-h00-ccc01-analog-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}