{"product_id":"yokogawa-pw484-10-24v-dc-power-module-centum-vp-system","title":"Yokogawa PW484-10 24V DC Power Module CENTUM VP System","description":"\u003ch2 data-start=\"89\" data-end=\"113\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"114\" data-end=\"631\"\u003eThe \u003cstrong data-start=\"118\" data-end=\"130\"\u003ePW484-10\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"153\" data-end=\"185\"\u003eDC-input power supply module\u003c\/strong\u003e engineered for the \u003cstrong data-start=\"205\" data-end=\"264\"\u003eYokogawa CENTUM VP Integrated Production Control System\u003c\/strong\u003e. Designed specifically for \u003cstrong data-start=\"292\" data-end=\"323\"\u003e24 V DC power architectures\u003c\/strong\u003e, it is ideal for plants utilizing centralized DC power systems or battery-backed supplies. The module converts external DC power into regulated internal voltages required by \u003cstrong data-start=\"498\" data-end=\"528\"\u003eField Control Units (FCUs)\u003c\/strong\u003e and I\/O expansion nodes, ensuring uninterrupted operation in mission-critical automation environments.\u003c\/p\u003e\n\u003chr data-start=\"633\" data-end=\"636\"\u003e\n\u003ch2 data-start=\"638\" data-end=\"665\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"667\" data-end=\"1306\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"667\" data-end=\"696\"\u003e\n\u003ctr data-start=\"667\" data-end=\"696\"\u003e\n\u003cth data-start=\"667\" data-end=\"679\" data-col-size=\"sm\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"679\" data-end=\"696\" data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"723\" data-end=\"1306\"\u003e\n\u003ctr data-start=\"723\" data-end=\"762\"\u003e\n\u003ctd data-start=\"723\" data-end=\"750\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"725\" data-end=\"749\"\u003eModel Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"750\" data-end=\"762\" data-col-size=\"md\"\u003ePW484-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"763\" data-end=\"804\"\u003e\n\u003ctd data-start=\"763\" data-end=\"783\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"765\" data-end=\"782\"\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"783\" data-end=\"804\" data-col-size=\"md\"\u003e24 V DC (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"805\" data-end=\"849\"\u003e\n\u003ctd data-start=\"805\" data-end=\"831\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"807\" data-end=\"830\"\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"831\" data-end=\"849\" data-col-size=\"md\"\u003e21.6–31.2 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"850\" data-end=\"925\"\u003e\n\u003ctd data-start=\"850\" data-end=\"876\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"852\" data-end=\"875\"\u003eConversion Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"876\" data-end=\"925\" data-col-size=\"md\"\u003eDC-to-DC conversion for internal system logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"926\" data-end=\"993\"\u003e\n\u003ctd data-start=\"926\" data-end=\"951\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"928\" data-end=\"950\"\u003eRedundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"951\" data-end=\"993\" data-col-size=\"md\"\u003eDual-redundant configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"994\" data-end=\"1052\"\u003e\n\u003ctd data-start=\"994\" data-end=\"1018\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"996\" data-end=\"1017\"\u003eFCU Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1018\" data-end=\"1052\" data-col-size=\"md\"\u003eAFV30S\/D, A2FV50S\/D, A2FV70S\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1053\" data-end=\"1132\"\u003e\n\u003ctd data-start=\"1053\" data-end=\"1077\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1076\"\u003eI\/O \/ Bus Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1077\" data-end=\"1132\" data-col-size=\"md\"\u003eANB10S\/D, ANB11S\/D Node Units; ANT10U Bus Repeaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1133\" data-end=\"1184\"\u003e\n\u003ctd data-start=\"1133\" data-end=\"1154\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1135\" data-end=\"1153\"\u003eCooling Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1154\" data-end=\"1184\" data-col-size=\"md\"\u003ePassive convection cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1185\" data-end=\"1245\"\u003e\n\u003ctd data-start=\"1185\" data-end=\"1209\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1187\" data-end=\"1208\"\u003eInrush Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1209\" data-end=\"1245\" data-col-size=\"md\"\u003eBuilt-in power-on surge limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1246\" data-end=\"1306\"\u003e\n\u003ctd data-start=\"1246\" data-end=\"1270\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1248\" data-end=\"1269\"\u003eStatus Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1270\" data-end=\"1306\" data-col-size=\"md\"\u003eFront-panel LED health indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1308\" data-end=\"1311\"\u003e\n\u003ch2 data-start=\"1313\" data-end=\"1344\"\u003eKey Operational Advantages\u003c\/h2\u003e\n\u003cp data-start=\"1345\" data-end=\"1856\"\u003eThe \u003cstrong data-start=\"1349\" data-end=\"1361\"\u003ePW484-10\u003c\/strong\u003e is optimized for \u003cstrong data-start=\"1379\" data-end=\"1427\"\u003ehigh-availability DC-powered control systems\u003c\/strong\u003e. In redundant installations, paired modules operate in load-sharing mode; if one unit fails, the remaining module instantly assumes full load without affecting controller logic or field communications. The \u003cstrong data-start=\"1634\" data-end=\"1652\"\u003e“-10” revision\u003c\/strong\u003e provides effective electrical isolation between the external DC supply and sensitive internal electronics, minimizing noise propagation and enhancing overall system stability within the FIO architecture.\u003c\/p\u003e\n\u003chr data-start=\"1858\" data-end=\"1861\"\u003e\n\u003ch2 data-start=\"1863\" data-end=\"1879\"\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp data-start=\"1881\" data-end=\"2103\"\u003e\u003cstrong data-start=\"1881\" data-end=\"1946\"\u003eQ: Can the PW484-10 be used in an AC-powered control cabinet?\u003c\/strong\u003e\u003cbr data-start=\"1946\" data-end=\"1949\"\u003eA: No. The PW484-10 is strictly a \u003cstrong data-start=\"1983\" data-end=\"2007\"\u003e24 V DC input module\u003c\/strong\u003e. For AC-powered systems (100–240 V AC), \u003cstrong data-start=\"2048\" data-end=\"2073\"\u003ePW481 or PW482 series\u003c\/strong\u003e power modules should be used.\u003c\/p\u003e\n\u003cp data-start=\"2105\" data-end=\"2303\"\u003e\u003cstrong data-start=\"2105\" data-end=\"2138\"\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr data-start=\"2138\" data-end=\"2141\"\u003eA: Yes. When installed in \u003cstrong data-start=\"2167\" data-end=\"2203\"\u003edual-redundant (“D” suffix) FCUs\u003c\/strong\u003e, the PW484-10 supports \u003cstrong data-start=\"2227\" data-end=\"2251\"\u003ehot-swap replacement\u003c\/strong\u003e, enabling maintenance without process interruption.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51653386436920,"sku":"PW484-10","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PW484-10.jpg?v=1769136357","url":"https:\/\/www.automodulexpert.com\/tr\/products\/yokogawa-pw484-10-24v-dc-power-module-centum-vp-system","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}