{"product_id":"yokogawa-ycb147-5-control-bus-communication-cable","title":"Yokogawa YCB147-5 Control Bus Communication Cable","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa YCB147-5\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed control bus interface cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP and VL net communication environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin CENTUM VP and CENTUM CS 3000 distributed control systems.\u003c\/p\u003e\n\u003cp\u003eThis 5-meter interconnect cable ensures deterministic data transmission between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Stations (FCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHuman Interface Stations (HIS)\u003c\/strong\u003e. Engineered with high-grade shielding and ruggedized construction, it maintains signal integrity in electrically noisy industrial environments and meets the strict latency requirements of Yokogawa’s proprietary control network architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCB147-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eControl Bus Interface Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Compatibility\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP, VL net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eHigh-density shielded multi-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eBraided copper + foil wrap (EMI\/RFI protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Impedance\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bending Radius\u003c\/td\u003e\n\u003ctd\u003e60 mm (static installation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003eFlame-retardant PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eFunctional Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDeterministic low-latency communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnhanced EMI\/RFI immunity for heavy industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRuggedized jacket for cabinet installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized for redundant Vnet\/IP architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication link between FCS and HIS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl cabinet internal bus wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVnet\/IP redundant bus configurations (Bus 1 \/ Bus 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCENTUM VP and CENTUM CS 3000 system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the YCB147-5 suitable for outdoor tray installations?\u003c\/strong\u003e\u003cbr\u003eA: No. It is designed for indoor cabinet or cable duct environments. Outdoor applications require additional protective conduit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this cable be used for Vnet\/IP redundancy?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Two YCB147-5 cables are typically installed per station to establish the dual redundant bus architecture (Bus 1 and Bus 2).\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51789549175096,"sku":"YCB147-5","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/YCB147-51.jpg?v=1770860833","url":"https:\/\/www.automodulexpert.com\/tr\/products\/yokogawa-ycb147-5-control-bus-communication-cable","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}