This 05701-A-0328 Relay Cards was manufactured by HONEYWELL, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
HONEYWELL
Part Number:
05701-A-0328
Product type:
Country of Origin:
USA
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
Collections:
 

Honeywell 05701-A-0328 Relay Cards

Configured for single-channel alarm and status relay switching in Honeywell Analytics control platforms, the Honeywell 05701-A-0328 (05701-A-0328 Relay Card) provides direct physical/electrical execution. This compact module converts analog or digital input signals into discrete electromechanical relay outputs for safety interlocks and alarm notification. Measuring 170 x 25 x 112 mm and weighing 0.165 kg, the DIN-rail mountable card incorporates front-panel LED indicators to provide real-time channel status and fault diagnostics across operating temperatures ranging from -40 to 85 deg C.

Hardware Specifications

Parameter Specification
Model 05701-A-0328
Part Number 05701-A-0328
Brand Honeywell
Category Relay Cards
Origin USA
Weight 0.165 kg
Dimensions 170 x 25 x 112 mm
Operating Temp -40 to 85 deg C
Power Consumption 1.8 W
Channel Count Single Channel
Signal Input Analog or Digital input signals
Output Type Relay / Discrete switching output
Mounting Type DIN rail mounting

DCS Process Control & Alarm Switching Architecture

The relay card operates within 4-20 mA HART and discrete monitoring architectures to execute deterministic alarm contact switching. High-grade channel-to-channel isolation networks separate signal input processing from field-side relay contact circuits, preventing electrical noise propagation and voltage spikes from affecting system backplanes. Integrated signal conditioning circuitry compensates for ambient thermal variations across -40 to 85 deg C, ensuring precise alarm trip thresholds and reliable relay contact execution under harsh environmental conditions.

Frequently Asked Questions

Q: Does removing or inserting the relay card on the DIN rail interrupt signal loops on adjacent cards?

A: No, individual DIN rail mounting and modular terminal block connections allow technicians to isolate and service a single card without disturbing adjacent control modules.

Q: How do the onboard LED indicators assist during field troubleshooting?

A: The front panel LEDs continuously reflect channel power, input signal presence, and relay energization states, allowing direct physical verification of alarm conditions without diagnostic software.

Field Installation Guidelines

Mount the relay card securely onto a standard 35 mm DIN rail, verifying that the rear retention clip seats fully to guarantee mechanical stability. Disconnect all loop power and external load circuits before attaching wiring to the terminal blocks. Route low-voltage analog and digital input cables in separate wire channels away from high-voltage relay switching lines, maintaining a minimum distance of 300 mm. Ground all cable shields at a single point on the enclosure earth ground bar to suppress electromagnetic interference and prevent circulating ground currents.

Quick Quotes Receive price & availability FAST from our dedicated customer service team.
Delivery Expedited, Freight, And International Shipping Available.
Condition 100% New with Original Package
Payment We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL.
Shipping Port ShangHai, Xiamen
Warranty 12 Months
Q: Is Our Pricing Competitive?
A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends.
Q: What Is the Warranty Period?
A: All our new and original products come with a standard one-year warranty.
Q: What Payment Methods Do We Accept?
A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them.
Q: What Shipping Methods Do We Use?
A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders.
Q: What Is Our Delivery Time?
A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule.
Q: How Do We Package the Goods?
A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes.
Q: How Can Customers Contact Us and Request a Quote?
A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote.
 

Recently Viewed

Express Shipping icon
Express Shipping
Rapid delivery for your urgent requirements.
Large stock icon
Extensive Inventory
Large stock for immediate dispatch.
Quality Assurance Icon
Quality Assurance
Authentic, top-grade PLC & DCS components.
Global Service icon
Global Service
Supporting clients worldwide with dependable service.