This DS200SDCIG1A DC Power Supply and Instrumentation Board was manufactured by GE FANUC, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
GE FANUC
Part Number:
DS200SDCIG1A
Country of Origin:
USA
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
Collections:
 

The GE DS200SDCIG1A, also cataloged as the DS200SDCIG1A DC Power Supply and Instrumentation Board, operates as a dedicated hardware component for power distribution and signal management within Mark V turbine control platforms.

Hardware Specifications

Parameter Specification
Model DS200SDCIG1A
Brand GE
Origin USA
Weight 2 kg
Dimensions 200 mm x 100 mm x 330 mm
Operating Temp Not specified
Power Consumption Not specified
Product Series Mark V

Profinet / EtherNet/IP Deterministic Networks

The GE DS200SDCIG1A functions within the Mark V control architecture, managing DC power regulation and instrumentation signal interfacing. The board maintains backplane bus communication velocity required for real-time turbine monitoring. Firmware flash compatibility is strictly defined by the revision level of the Mark V control rack; installation requires alignment with the existing controller's I/O configuration to avoid communication interrupts or bus addressing errors. The instrumentation circuitry is designed for high-density signal processing, ensuring that the backplane interface remains deterministic during varying load conditions on the DC power supply rails.

Frequently Asked Questions

Q: Does this board support hot-swapping under full rack load?

A: No. The board must be completely isolated from the DC supply bus prior to insertion or removal to prevent electrical arcing and potential damage to the backplane communication pins.

Q: Is the firmware on this board field-upgradable?

A: Firmware updates must be performed using the GE-approved serial interface tools. Ensure that the controller is in a safe, non-operational state before initiating any flash memory write operations to prevent data corruption.

Field Installation Guidelines

  • Mounting: The board must be inserted into the designated Mark V rack slot. Ensure that the retention clips are fully engaged to maintain structural stability and electrical continuity with the backplane.
  • Shielding: All instrumentation signal cables must use shielded twisted-pair wiring. Terminate the shield at the cabinet ground bus bar to prevent common-mode noise from affecting signal accuracy.
  • Grounding: Verify that the metal chassis of the module is properly bonded to the cabinet ground to ensure protection against electromagnetic interference.
  • Thermal Management: While specific operating temperatures are not provided, ensure that air circulation within the cabinet is unrestricted. Maintain a minimum clearance of 50 mm above and below the module to allow for heat dissipation.
Quick Quotes Receive price & availability FAST from our dedicated customer service team.
Delivery Expedited, Freight, And International Shipping Available.
Condition 100% New with Original Package
Payment We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL.
Shipping Port ShangHai, Xiamen
Warranty 12 Months
Q: Is Our Pricing Competitive?
A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends.
Q: What Is the Warranty Period?
A: All our new and original products come with a standard one-year warranty.
Q: What Payment Methods Do We Accept?
A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them.
Q: What Shipping Methods Do We Use?
A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders.
Q: What Is Our Delivery Time?
A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule.
Q: How Do We Package the Goods?
A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes.
Q: How Can Customers Contact Us and Request a Quote?
A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote.
 

Recently Viewed

Express Shipping icon
Express Shipping
Rapid delivery for your urgent requirements.
Large stock icon
Extensive Inventory
Large stock for immediate dispatch.
Quality Assurance Icon
Quality Assurance
Authentic, top-grade PLC & DCS components.
Global Service icon
Global Service
Supporting clients worldwide with dependable service.